Walk in Freezer Flame Proof Chamber
- Home
- Products
- Battery Testing Sector
- Walk in Freezer Flame Proof Chamber
- Algal Growth Chamber
- Accelerated Ageing Chamber
- Arabidopsis Growth Chamber
- Photo Stability Chamber
- Drosophila Chamber
- Seed Germinator Single Chamber
- Seed Germinator Dual Chamber
- Insect Growth Chamber
- Walk In Seed Germinator Chamber
- Laminar Air Flow
- Plant Growth Chamber
- Walk In Plant Growth Chamber
- Accelerated Ageing Oven
- Cooling Cabinet Model : SRL / CCH-02
- Accelerated Weathering Chamber Model SRL / AWC-12
- Thermal Hot and Cold Chamber Model : SRL / HCCH-02
- Humidity Chamber MODEL : SRL / HC-09
- Horizontal Rectangular Autoclave / Sterilizer Model : SRL/AC-58
- Seed Storage Cabinet Model : SRL / SSC-22
- Cold Chamber Model : SRL / CCH-02
- Walk In Humidity Chamber Model : SRL / WIHC-12
- Walk In LN2 Chamber Model : SRL / WILN2-12
- Walk In Hot & Cold Chamber
Our Brouchers
Download
Get in Touch
Location:
goregaon (East) Mumbai, Maharashtra- 400063.
Mail Us On :
sales@srlabinstruments.com
info@srlabinstruments.com
Make a Call :
022 2685 8753
022 26858362
Walk in Freezer Flame Proof Chamber
Model No : SRL / WIDF-12
Ecocentric System :
Chamber runs on the basis of Dewpoint control. Less deviations
during short-term door opening & power failure. Less utility area
Increased storage area. Low operating cost. Minimum power &
water consumption. Reduced deviations. Less breakdowns due
to standby refrigeration & humidification system. Due to PLC
HMI & controlling through microprocessor based PID Temp. &
RH operations the on time of both Temp. & RH system is
reduced & efficiency of this system is increased with reduced
energy consumption.
Temp. Range :
-25°C
Accuracy : ±0.2 C, Uniformity : + 1 C, Resolution : 0.1 C
All chamber meet the ICH Q1A guidelines for testing including :
Long Term : -25 C.
Intermediate : -25 C.
Accelerated : -25 C.
Accuracy : ±0.2 C, Uniformity : + 1 C, Resolution : 0.1 C
All chamber meet the ICH Q1A guidelines for testing including :
Long Term : -25 C.
Intermediate : -25 C.
Accelerated : -25 C.
Construction :
MOC of the Chamber will be: Double walled Chamber with Inner of mirror finish stainless steel 304 grade & outer of CRCA duly powder coated, PUF Insulation in between two walls.
Door: Flush type doors of metal surfaces (as per above specification of metal) with proper puff insulation of above mentioned standard. Doors shall have magnetic snap-in perimeter gasket or its equivalent, self-closing cam lift gravity hinges or its equivalent, a posi-seal door closure or its equivalent. Door shall have key lockable latch handle. Doorjambs shall be made fiberglass reinforced plastic or any other suitable material compatible with constructed door.
- Flooring: 2 mm aluminum chequer plates
- The unit will be made of double walled leak proof metal door with lock, with a provision of opening door from inside.
- Forced air circulation for uniform temperature.
Door: Flush type doors of metal surfaces (as per above specification of metal) with proper puff insulation of above mentioned standard. Doors shall have magnetic snap-in perimeter gasket or its equivalent, self-closing cam lift gravity hinges or its equivalent, a posi-seal door closure or its equivalent. Door shall have key lockable latch handle. Doorjambs shall be made fiberglass reinforced plastic or any other suitable material compatible with constructed door.
Trays & Racks :
Removable SS perforated trays are provided, adjustable and
will slide out for easy clean up. Assembled Stainless Steel racks
to accommodate trays
Power Supply :
Single phase 230V AC, 50 Hz / Three phase 440V AC, 50 Hz.
Features :
Spark free Interior & Exterior. Safety feature with alarms.
Flame proof parts : Motors / HMI / Light Fitting / Control Panel / Sensors.
Fire System : Automatic Start Function / AV Alarms/Hooters / Flame & smoke detection sensors.
Complete with validation & Test Certificates.
Flame proof parts : Motors / HMI / Light Fitting / Control Panel / Sensors.
Fire System : Automatic Start Function / AV Alarms/Hooters / Flame & smoke detection sensors.
Complete with validation & Test Certificates.
Air Circulation : [Laminar Type]
The chamber is provided with best air circulation to
give better temperature uniformity this is achieved by using one
set of motor & blower in baffle wall Compartment to push treated
air in working chamber. This system gives better than 1 deg c.
temperature uniformity in working chamber, evaporator, heaters
& steam injection system is from back side, behind baffle wall,
the air circulation blower is also fitted in this compartment only.
This arrangement helps to mix steam and air together and pass
well mixed air inside the working chamber. Due to above system
the temperature and humidity (R.H.) in complete chamber
almost remains equal. Uniform forced air circulate across the
shelf via air diffusers on the top wall. Uniform horizontal or
vertical airflow shall be provided for maintaining uniform temp.
Refrigeration system : (Air Cooled)
Emerson / Bitzer /Danfoss/Tecumseh : make compressors,
1 stage cooling system for TEMP. & Humidity Control. All
accessories such as HPCO/LPCO, Oil Separators, Dryers,Relays,
OLP etc. of Danfoss/Tecumseh Emerson Make.
CFC free refrigerant to be used to comply with the New
Environmental Regulation. Will have suitable tonnage compressor
for maintain temperature with lights on. Will have hermetically
sealed condensing unit compressor coupled with Evaporation coil
and condenser, safe guarded by time delay circuit. Cabinet shall
be supplied with air-cooled condensing unit with extended
compressor life and close temperature control. Cooling system
will be split type to place condenser unit in a ventilated area to
avoid hot air in growth chamber. Cooled air shall be delivered in
such a way to reduce or eliminate condensation within media
dishes and to provide maximum uniformity In different research
vessels. This may be through silent and durable fan motors or
through any kind of advanced air diffusers. Air Cooled Condenser
with solenoid & LP to pass hot gas to the chamber for uniformity
& long life of compressor for continuous usage. Phenolic coating
for cooling & condensing coils (All weather proof).
Safety Features :
In case of fire inside the chamber, insert gas will be purged. Automatic start function.
Flame & smoke detection sensors installed inside the walk in chamber. No risk of personal Injury.
Faster than other extinguishing systems using natural gases. Extinguishing storage system. Electrical non-conducting.
Best Environmental protection by HFCs.
No clean up required after discharge.
Modular design using multiplex extinguishing agent storage containers.
Other walk in chamber also available in Flameproof
Unit will be provided with safety devices for temperature and humidity overshoot in case of malfunction.
Built-in temp. Deviation, audio/visual alarms. Safety thermostat for over shooting of temp. Safety circuit to cut off the whole system.
Interior safety release knob for door.
Hooter with switch inside (Alarm).
Flame & smoke detection sensors installed inside the walk in chamber. No risk of personal Injury.
Faster than other extinguishing systems using natural gases. Extinguishing storage system. Electrical non-conducting.
Best Environmental protection by HFCs.
No clean up required after discharge.
Modular design using multiplex extinguishing agent storage containers.
Other walk in chamber also available in Flameproof
Unit will be provided with safety devices for temperature and humidity overshoot in case of malfunction.
Built-in temp. Deviation, audio/visual alarms. Safety thermostat for over shooting of temp. Safety circuit to cut off the whole system.
Interior safety release knob for door.
Hooter with switch inside (Alarm).
Controller :
PID Action: Provides Precise Temperature, Maintain Uniform
And Accurate Growth Environment, Timer, Alarm, Auto-Tuning
And Auto Start Stop Function. Technical Design and Construction
Silent Fan Motor to Maintain Uniform Temperature Over Temp.
and Current Protection Capability Ensure User Safety, Adjustable
Sliding Rack, Alert Unexpected Interruption Of Electrical Power
Or Unauthorized Change.
Optional : PLC with HMI Control system with touch screen display & HMI for data Storage, data logger reading & audit trail, Door access & SMS records, Email alert. Data Logger 1 temp + 1 RH. Data Logger with LCD display window capable to store non volatile data memory up to 5000 readings with audit trail facility complies 21 CFR Part 11. Change over to stand by system automatically as per schedule or on detecting fault with current system Temp. & Humidity overshoot and under shoot protection Mobile Alarm system, Door Access, system setting reset , Graph, SMS, Email alert, etc.
Optional : PLC with HMI Control system with touch screen display & HMI for data Storage, data logger reading & audit trail, Door access & SMS records, Email alert. Data Logger 1 temp + 1 RH. Data Logger with LCD display window capable to store non volatile data memory up to 5000 readings with audit trail facility complies 21 CFR Part 11. Change over to stand by system automatically as per schedule or on detecting fault with current system Temp. & Humidity overshoot and under shoot protection Mobile Alarm system, Door Access, system setting reset , Graph, SMS, Email alert, etc.
Stability Data Management Software 21 CFR Part 11 Compliance :
21 CFR part 11 Compliance.
Online & Offline Data representation in Tabular as well as Graphical Form.
Separate display formats for Real time Data & Acquired Data for single or multiple chambers.
Mean Kinetic Value (MKT) as per USP 24 NP 19 – Daily, Weekly, Monthly
Online & Offline Data representation in Tabular as well as Graphical Form.
Separate display formats for Real time Data & Acquired Data for single or multiple chambers.
Mean Kinetic Value (MKT) as per USP 24 NP 19 – Daily, Weekly, Monthly
Validation :
With 8 Temp. & 8 RH point scanner with sensor printer
interface & Data storage facility, 24 hrs with load & 24 hrs
w/o load, 8 hrs power failure test, 15 mins door opening
test for one condition only.
Documentation :
To comply with the documentation requirements, we provide IQ, OQ & PQ protocols to be executed before taking the chamber in to for regular use, and support the supply with the following documents with the detail operational and service manual.
Standard Operating Procedure (SOP)
Operational Manual for Controller
IQ,PQ,OQ protocols certificate.
Calibration certificate of all controlling modules with traceable to NABL / ERTL accredited labs.
Certificate of MOC.
Test Report of chamber prior to supply with mapping certificate. wiring diagram for ease of service maintenance.
Standard Operating Procedure (SOP)
Operational Manual for Controller
IQ,PQ,OQ protocols certificate.
Calibration certificate of all controlling modules with traceable to NABL / ERTL accredited labs.
Certificate of MOC.
Test Report of chamber prior to supply with mapping certificate. wiring diagram for ease of service maintenance.
Documentation :
- MSME AWARD FOR BEST MANUFACTURING PRACTICES – 2023
- ISO/IEC 17025: 2017 / Electrical Safety IEC 61010.
- ISO 45001:2018 / ISO 14001:2015 & WHO-GMP.
- ISO 9001:2015 certified Co. & CE marked product.
- RoHS 2002/95/EC / UL (QAMS Certification).
- US FDA Certification.
- NSIC & MSME registered.
- D&B registered (Financial Certification).