This chamber product is frequently used for research application such as lighting for plant pathology research and seedling germination and development.
Chamber runs on the basis of Dewpoint control. Less deviations during short-term door opening & power failure. Less utility area Increased storage area. Low operating cost. Minimum power & water consumption. Reduced deviations. Less breakdowns due to standby refrigeration & humidification system. Due to PLC HMI & controlling through microprocessor based PID Temp. & RH operations the on time of both Temp. & RH system is reduced & efficiency of this system is increased with reduced energy consumption.
The chamber is provided with best air circulation to give better
temperature uniformity this is achieved by using one set of motor
& blower in baffle wall Compartment to push treated air in working
chamber. This system gives better than 1 deg c. temperature
uniformity in working chamber, evaporator, heaters & steam
injection system is from back side, behind baffle wall, the air
circulation blower is also fitted in this compartment only. This
arrangement helps to mix steam and air together and pass well
mixed air inside the working chamber. Due to above system the
temperature and humidity (R.H.) in complete chamber almost
remains equal.
Uniform horizontal or vertical airflow shall be provided for
maintaining uniform temperature and RH in the room. System for
adjustable forced air exchange shall be provided with up to 20 air
exchanges per hour of fresh air to the room or its equivalent and
an option to shut it down when not required.
Controls temperature, lighting, humidity and Co2 with
High-definition Touch Screen for real time graphing. Programs can
be configured to run in real time or elapsed time. Ramping and
non-ramping program methods shall be implemented. Multiple
programs can be linked creating complex sequence to simulate
natural conditions. Trouble shooting with on board
diagnostics. Dual experiment protection via integrated yet
independent temperature limit shutdown. It shall auto-restart when
temp inside the chamber comes to normal. Temperature low and
high deviation alarm. Ambient temperature monitoring.
Alarm (audio and visual). Power failure event logging. Auto restart
in case of power failure with inbuilt battery to protect memory.
Provides Precise Temperature, Maintains Uniform And Accurate
Growth Environment, Timer, Alarm, Auto-Tuning And Auto Start
Stop Function. Technical Design and Construction Silent Fan
Motor to Maintain Uniform Temperature Over Temperature and
Current Protection Capability Ensure User Safety, Adjustable
Sliding Rack, And Alert Unexpected Interruption Of Electrical
Power Or Unauthorized Change.
PLC with HMI: Real-Time Connectivity : Users have complete
control of chamber using the PC connected through LAN,
Including creating / editing programs and changing operating
tolerances. Shall have feature to run in real time or elapsed
time. Ambient temp. Monitoring. 24 hrs. Chamber monitoring.
Temp. Will rise gradually to reach the temp. In fixed time, remain
in fixed temp. For Known period of time & then decreased back to
initial temp, in fixed time internal gradually. Stepwise
Programmable Controller with 50 or more programs Provides
Automatic Operation of Variable Temperature, Humidity Value,
50 Or More Cycles with Minimum 100 Sections in Each Cycle,
Data logger with RS 485/232 port for logging & transfer of data.
Auto restart, power failure event logging, memory protection
S.M.A.R.T/ SELF diagnostics system. Data collected from each
logger shall be transferred to central data storage unit. Shall
provide central data storage unit with facility to retrieve the stared
data at any time. Multiple programs linked together to simulate
natural condition. Control system shall have audio/audiovisual
warning/alarm when set temperature/RH is below or above the set
values. Ethernet communication port. Ambient temp. Monitoring.
Over Temperature and Current Protection Capability Ensure User
Safety, Adjustable Sliding Rack, Water Level Sensor Alert Control
System. Total no of output: 23 channels. Alert Unexpected
Interruption of Electrical Power or Unauthorized Change.
4 digit password lock.
USFDA approved 21 CFR compliance software] :
PLC with HMI Control system with touch screen display & HMI for
data Storage, data logger reading & audit trail, Door access &
SMS records, Email alert. Data Logger 1 temp + 1 RH. Data
Logger with LCD display window capable to store non volatile
data memory up to 5000 readings with audit trail facility USFDA
approved 21 CFR Part 11 compliance software. Change over to
stand by system automatically as per schedule or on detecting
fault with current system Temperature & Humidity overshoot and
under shoot protection Mobile Alarm system, Door Access,
system setting reset , Graph, SMS, Email alert, etc.
First time in India developed by SR Lab Instruments.
Standby Refrigeration, Standby Humidification & Standby safety
controller with auto changeover, In case of failure of the main
system, To run the system for a longer with uninterrupted
operation.
Also USFDA approved 21 CFR compliance software, where in
case of temp. & RH fluctuation, SMS & Email alert shall be sent
to registered user nos and minute details of operation of the
chamber can be downloaded weekly, Monthly or Quarterly.
Up to 1400 μmoles/m²/sec
(I)Lights are mounted on shelves / side walls of the chamber.
(ii)Programmable ON/OFF lights for day/night effect. [10-100%]
(iii)Option for Lighting the each tier of the plant growth chamber
with properly spaced RGB-IR lights to impart uniform light
intensity on the shelf. (Light intensity-As per requirement)
Programming and control of the lighting is done via PLC with
HMI control system.
(iv)Programmable event with suitable UV-A /UV-B lights in the
chamber.
(v)Lighting shall be dimmable either with open loop or closed loop
controls. (Optional)
Lamp heat will be removed by conditioning system. Shelves will be
lighted with fluorescent / Incandescent / LED with balanced
spectrum for Uniform Light intensity, measured 6 inches from
lamps on programmable on/off light events.
Light meter for display & recording of light output. (Optional)
Optional: Ability to dim light intensity from 10 to 100 percent in
one-percent increments, with the option to add individually
controlled light channels for multiple-tier chambers . This
dimmable lighting system provides more uniform light distribution
throughout the chamber with a more balanced spectrum for
general growth chamber.
Ability to control each color in a multi color lamp bank. Each
standard lamp bank shall consist of multi-color LEDs consisting of
▪ Cool white (6500K) LEDs / Warm White (3500K) LEDs
▪ Red (650-670nm) LEDs
▪ Blue (451nm) LEDs
▪ Far Red (720-740nm) LEDs
▪ Green (510-550nm) LEDs
▪ UV-A (390nm) LEDs
▪ UV-B (310nm) LEDs
▪ Violet (430nm) LEDs
LED PCB material. Alluminium plating steel, intensity adjustable
from 10 to 100%. Programmable in intensity & time (photoperiod),
Low heat load, longer lifespan compared to HPS or
fluorescent bulbs.
(Option to customize (add / remove) the light as per requirement)
PAR light sensor: Photosyntheticlly Active Radiation
Sensor. [Optional]
MOC of the Chamber will be: Double walled Chamber with Inner of
stainless steel 304 grade & outer of CRCA duly powder coated,
PUF Insulation in between two walls.
(i) Double door, inner door of glass with frame & silicon gasket sealing,
outer door metallic with PUF insulation.
(ii)The unit will be made of double walled leak proof metal door with lock,
with a provision of opening door from inside.
(iii) Forced air circulation for uniform temperature.
(iv) Lockable & Movable PU wheels for easy movement.
Insulation of Walls, ceiling and floor : 80mm thick puff panels with
puff in-place density of minimum of 1kg per cubic foot. Exterior metal
surface of insulation puff panels or its equivalent shall be of minimum 24
gauge embossed white galvanized steel or its equivalent. Interior metal
surface of insulation puff panels or its equivalent shall be of minimum 26
gauge smooth steel with baked white enamel finish or its equivalent.
Exterior and interior metal surface shall not have metal-to- metal bonding.
Door : Flush type doors of metal surfaces (as per above specification of
metal) with proper puff insulation of above mentioned standard or its
equivalent. Doors shall have magnetic snap-in perimeter gasket or its
equivalent, self-closing cam lift gravity hinges or its equivalent, a posi-seal
door closure or its equivalent. Door shall have key lockable latch handle.
Doorjambs shall be made fiberglass reinforced plastic or any other suitable
material compatible with constructed door
Emerson /Danfoss/Tecumseh: make compressors, 1 stage cooling system for TEMP. & Humidity Control. All accessories such as HPCO/LPCO, Oil Separators, Dryers, Relays, OLP etc. of Danfoss/Tecumseh Emerson Make. CFC free refrigerant to be used to comply with the New Environmental Regulation. Will have suitable tonnage compressor for maintain temperature with lights on. Will have hermetically sealed condensing unit compressor coupled with Evaporation coil and condenser, safe guarded by time delay circuit. Cabinet shall be supplied with air-cooled condensing unit with extended compressor life and close temperature control. Cooling system will be split type to place condenser unit in a ventilated area to avoid hot air in growth chamber. Cooled air shall be delivered in such a way to reduce or eliminate condensation within media dishes and to provide maximum uniformity In different research vessels. This may be through silent and durable fan motors or through any kind of advanced air diffusers. Air Cooled Condenser with solenoid & LP to pass hot gas to the chamber for uniformity & long life of compressor for continuous usage. Phenolic coating for cooling & condensing coils (All weather proof).
Sensors : Rotronic Make Hygroclip non condensing type sensor for RH and PT-100 ‘A’ class for temp. calibrated from ERTL / NABL accredited labs.
-10°C to +60°C , (lights ON & OFF Condition)
Resolution : 0.1°C, Accuracy : ±0.2°C, Uniformity : ±0.5°C to ±1°C
Relative humidity from 10% to 98%,
Resolution : 0.1%, Accuracy : ±2% , Uniformity : ±3%.
Single phase 230V AC, 50 Hz / Three phase 440V AC, 50 Hz.
Good quality SS tubular heaters.
Will consist of pan type humidifier tank fitted with boiler heaters, and give alarm if fault occurs or Ultrasonic Humidification System. Water reservoir tank will be connected to the humidifier. De-humidification coils are installed below the cooling coils for lower humidity.
Co2 Application : Complete package with CO2 NDIR Sensor for
packaging between range of 250 PPM to 2000 PPM with CO2
cylinder & regulator directly operated from PLC automatically.
1. Servo controlled voltage stabilizer.
2. PAR Light Sensor.
3. Dimmable light control.
4. Suitable RO system.
5. UPS backup with batteries to run the equipment in case of
power failure.
Perforated / Bar type stainless steel trays & can be lifted easily
for cleaning. Adjustable up to 0.5 inch increment / decrement.
Growth area per shelf : As per requirement.
Total growth area : As per requirement.
Growth height per tier : As per requirement.
2 minute compressor “on” delay timer to safeguard the compressor.
Compressors overload relay protector. Electronic low water level cut
off device to cut off the supply to boiler heater in case of low water
level. Safety Temp. Controller. MCB for mains.
(I) Unit will be provided with safety devices for temperature and
humidity overshoot in case of malfunction.
(ii) Built-in temp. Deviation, audio/visual alarms.
Safety thermostat for over shooting of temp. Safety circuit to cut
off the whole system.
(iii) OLP (Overload Protector) & Time delay Circuit for safety of
compressors.
(iv) HRC fuses for compressors, Heaters & Mains.
ISO 9001:2015 Certified Co. D&B registered & CE mark
product.
ISO 14001:2015 & WHO-GMP.
NSIC & MSME registered.
Electrical safety compliance 61010.
Calibration & validation certificates traceable to NABL / ERTL
accredited labs.
To comply with the documentation requirements, we provide
IQ, OQ & PQ protocols to be executed before taking the chamber
in to for regular use, and support the supply with the following
documents with the detail operational and service manual.
Standard Operating Procedure (SOP)
Operational Manual for Controller
IQ,PQ,OQ protocols certificate.
Calibration certificate of all controlling modules with traceability.
Certificate of MOC.
Test Report of chamber prior to supply with mapping certificate.
wiring diagram for ease of service maintenance.
Model SRL / AGC – 11 | Internal Dimension (W X D X H)(cms) | Capacity Ltrs |
---|---|---|
AGC -A | 45 x 45 x 50 | 100 |
AGC -B | 50 x 50 x 80 | 200 |
AGC -C | 55 x 55 x 100 | 300 |
AGC -D | 60 x 60 x 110 | 400 |
AGC -E | 60 x 60 x 140 | 500 |
AGC -F | 70 x 60 x 145 | 600 |
AGC -G | 80 x 65 x 135 | 700 |
AGC -H | 75 x 75 x 145 | 800 |
AGC -I | 80 x 75 x 150 | 900 |
AGC -J | 80 x 80 x 155 | 1000 |
AGC -K | 85 x 80 x 160 | 1100 |
AGC -L | 90 x 83 x 160 | 1200 |