Bacteriological Incubator
Bacteriological Incubator
Application :
Equipment specially designed & suitable for Electronic Industry, Space Programs Research, Research Labs, Blood Banks, Biological Specimens, Serum, Vaccines, Research Laboratories Medical Specimens, Clinical Samples, Industrial research etc, for testing under extreme low temp. conditions
Construction :
Constructed with CRCA sheets of suitable gauge & angle iron frames are provided, construction is of double or triple walled. Inner is made of S.S 304 & Outer is M.S Non-contaminant epoxy powder coated with thick insulation of resin-bonded glass slabs are filled in between the two walls. Double walled door with heavy duty hinges, spring & roller type latch catch as locking device. Adjustable ventilators are provided for letting the moisture go out.







Temperature Range :
+35° C to +60°C
Accuracy : +0.2° C
Air Circulation :
Efficient forced air circulating system is provided to ensure uniform conditions inside the chamber.
Controls
Standard PID : Provides Precise Temperature, Maintain Uniform And Accurate Growth Environment, Timer, Alarm, Auto-Tuning And Auto Start Stop Function. Technical Design and Construction Silent Fan Motor to Maintain Uniform Temperature Over Temp. and Current Protection Capability Ensure User Safety, Adjustable Sliding Rack, Alert Unexpected Interruption Of Electrical Power Or Unauthorized Change.
Safety Features :
Built-in temp. deviation audio / visual alarm. Safety thermostat for over shoot temp. cut off, safety circuit to cut off the whole system in case of malfunction
Certification :
Special Care :
A suitable K.V.A Servo Controlled Voltage Stabilizer is strongly recommended in case of voltage fluctuations.
Data Logger :
Data logging with RS-232/485 inter phase, inbuilt system monitoring and reporting technology SMART diagnostic software with audio-visual alarm for temperature deviation power fail more than 5 Degree C and system fail & low battery, Battery backup for alarm during power failure, password access for temp. set point alteration.
Documentation :
Standard Operating Procedure (SOP)
Operational Manual for Controller
IQ,PQ,OQ protocols certificate.
Calibration certificate of all controlling modules with traceability.
Certificate of MOC.
Test Report of chamber prior to supply with mapping certificate.
wiring diagram for ease of service maintenance.
Model No: SRL-BI -15 | BI-A | BI-B | BI-C | BI-D | BI-E |
---|---|---|---|---|---|
Capacity Ltrs | 65 | 90 | 125 | 215 | 325 |
Chamber Size (cms | 40 x 40 x 40 | 45 x 45 x 45 | 50 x 50 x 50 | 60 x 60 x 60 | 60 x 60 x 90 |