Mould Growth Chamber Model No : SRL / MGC - 01
- Home
- Products
- Mould Growth Chamber Model No : SRL / MGC - 01
- Algal Growth Chamber
- Accelerated Ageing Chamber
- Arabidopsis Growth Chamber
- Photo Stability Chamber
- Drosophila Chamber
- Seed Germinator Single Chamber
- Seed Germinator Dual Chamber
- Insect Growth Chamber
- Walk In Seed Germinator Chamber
- Laminar Air Flow
- Plant Growth Chamber
- Walk In Plant Growth Chamber
- Accelerated Ageing Oven
- Cooling Cabinet Model : SRL / CCH-02
- Accelerated Weathering Chamber Model SRL / AWC-12
- Thermal Hot and Cold Chamber Model : SRL / HCCH-02
- Humidity Chamber MODEL : SRL / HC-09
- Horizontal Rectangular Autoclave / Sterilizer Model : SRL/AC-58
- Seed Storage Cabinet Model : SRL / SSC-22
- Cold Chamber Model : SRL / CCH-02
- Walk In Humidity Chamber Model : SRL / WIHC-12
- Walk In LN2 Chamber Model : SRL / WILN2-12
- Walk In Hot & Cold Chamber
Our Brouchers
Download
Get in Touch
Location:
goregaon (East) Mumbai, Maharashtra- 400063.
Mail Us On :
sales@srlabinstruments.com
info@srlabinstruments.com
Make a Call :
022 2685 8753
022 26858362
Mould Growth Chamber Model No : SRL / MGC - 01
Application :
A mould growth chamber can be used to evaluate the mold degree and anti-mold ability of electronic products, durability and climate of electrical and electronic components, corrosion of mechanical assemblies, paints, varnishes, and packages, botanical and zoological investigations, chemicals, drugs, pharmaceuticals, cosmetics, and medicine. Mold growth chambers are used for biological culture and bacteria storage in colleges, universities, and scientific research laboratories.
Ecocentric System :
Chamber runs on the basis of Dewpoint control. Less deviations during short-term door opening & power failure. Less utility area Increased storage area. Low operating cost. Minimum power & water consumption. Reduced deviations. Less breakdowns due to standby refrigeration & humidification system. Due to PLC HMI & controlling through microprocessor based PID Temp. & RH operations the on time of both Temp. & RH system is reduced & efficiency of this system is increased with reduced energy consumption.
Temp. & Humidity Range :
+10°C to +60°C
0 Resolution : 0.1 C, Accuracy : 0.2°C, Uniformity : + 2°C
Humidity Range : 40% to 98% RH,
Resolution : 0.1%, Accuracy : + 1%, Uniformity : + 3%
0 Resolution : 0.1 C, Accuracy : 0.2°C, Uniformity : + 2°C
Humidity Range : 40% to 98% RH,
Resolution : 0.1%, Accuracy : + 1%, Uniformity : + 3%
Salient Features : [Optional]
First time in India developed by SR Lab Instruments.
Standby Refrigeration, Standby Humidification & Standby safety
controller with auto changeover, In case of failure of the main
system, To run the system for a longer with uninterrupted
operation.
Also USFDA approved 21 CFR compliance software, where in case of temp. & RH fluctuation, SMS & Email alert shall be sent to registered user nos and minute details of operation of the chamber can be downloaded weekly, Monthly or Quarterly.
Also USFDA approved 21 CFR compliance software, where in case of temp. & RH fluctuation, SMS & Email alert shall be sent to registered user nos and minute details of operation of the chamber can be downloaded weekly, Monthly or Quarterly.
Construction :
MOC of the Chamber will be: Double walled Chamber with Inner of stainless steel 304 grade & outer of CRCA duly powder coated,
PUF Insulation in between two walls
Insulation of Walls, ceiling and floor : 80mm thick puff panels with puff in-place density of minimum of 1kg per cubic foot. Exterior metal surface of insulation puff panels or its equivalent shall be of minimum 19 gauge embossed white stainless steel or its equivalent. Interior metal surface of insulation puff panels or its equivalent shall be of minimum 19 gauge stainless steel with baked white enamel finish or its equivalent. Exterior and interior metal surface shall not have metal-to- metal bonding.
Door : Flush type doors of metal surfaces (as per above specification of metal) with proper puff insulation of above mentioned standard or its equivalent. Doors shall have magnetic snap-in perimeter gasket or its equivalent, self-closing cam lift gravity hinges or its equivalent, a posi-seal door closure or its equivalent. Door shall have key lockable latch handle. Doorjambs shall be made fiberglass reinforced plastic or any other suitable material compatible with constructed door
- Double door, inner door of glass with frame & silicon gasket sealing, outer door metallic with PUF insulation
- The unit will be made of double walled leak proof metal door with lock, with a provision of opening door from inside
- Forced air circulation for uniform temperature.
- Lockable & Movable PU wheels for easy movement.
Insulation of Walls, ceiling and floor : 80mm thick puff panels with puff in-place density of minimum of 1kg per cubic foot. Exterior metal surface of insulation puff panels or its equivalent shall be of minimum 19 gauge embossed white stainless steel or its equivalent. Interior metal surface of insulation puff panels or its equivalent shall be of minimum 19 gauge stainless steel with baked white enamel finish or its equivalent. Exterior and interior metal surface shall not have metal-to- metal bonding.
Door : Flush type doors of metal surfaces (as per above specification of metal) with proper puff insulation of above mentioned standard or its equivalent. Doors shall have magnetic snap-in perimeter gasket or its equivalent, self-closing cam lift gravity hinges or its equivalent, a posi-seal door closure or its equivalent. Door shall have key lockable latch handle. Doorjambs shall be made fiberglass reinforced plastic or any other suitable material compatible with constructed door
Refrigeration system : (Air Cooled)
Emerson / Danfoss / Tecumseh: make compressors,
1 stage cooling system for TEMP. & Humidity Control. All
accessories such as HPCO/LPCO, Oil Separators, Dryers, Relays,
OLP etc. of Danfoss/Tecumseh Emerson Make.
CFC free refrigerant to be used to comply with the New
Environmental Regulation. Will have suitable tonnage compressor
for maintain temperature with lights on. Will have hermetically
sealed condensing unit compressor coupled with Evaporation coil
and condenser, safe guarded by time delay circuit. Cabinet shall be
supplied with air-cooled condensing unit with extended compressor
life and close temperature control. Cooling system will be split type
to place condenser unit in a ventilated area to avoid hot air in
growth chamber. Cooled air shall be delivered in such a way to
reduce or eliminate condensation within media dishes and to
provide maximum uniformity In different research vessels. This may
be through silent and durable fan motors or through any kind of
advanced air diffusers. Air Cooled Condenser with solenoid & LP to
pass hot gas to the chamber for uniformity & long life of compressor
for continuous usage. Phenolic coating for cooling & condensing
coils (All weather proof).
Controller :
PID Action : Provides Precise Temperature, Maintain Uniform
And Accurate Growth Environment, Timer, Alarm, Auto-Tuning
And Auto Start Stop Function. Technical Design and Construction
Silent Fan Motor to Maintain Uniform Temperature Over
Temperature and Current Protection Capability Ensure User
Safety, Adjustable Sliding Rack, Alert Unexpected Interruption
Of Electrical Power Or Unauthorized Change.
Optional : [PLC with HMI TFT screen]
PLC-HMI Control system with touch screen display & HMI for
data Storage, Stepwise Programmable Controller with 50 or
more programs Provides Automatic Operation of Variable
Temperature, Humidity Value, 100 Or More Cycles with Minimum
100 Sections in Each Cycle. Data logger with RS 485/232 port
for logging & transfer of data. Auto restart, power failure event
logging, memory protection S.M.A.R.T/ SELF diagnostics
system. Control system shall have audio/audiovisual warning /
alarm when set temperature/RH is below or above the set
values. Ethernet communication port. Ambient temp. Monitoring.
Over Temperature and Current Protection Capability Ensure
User Safety, Adjustable Sliding Rack, Water Level Sensor Alert
Control System. Total no of output: 23 channels. Alert
Unexpected Interruption of Electrical Power or Unauthorized
Change.4 digit Password lock.
Air Circulation : [Laminar Type]
The chamber is provided with best air circulation to give better
temperature uniformity this is achieved by using one set of motor
& blower in baffle wall Compartment to push treated air in working
chamber. This system gives better than 1 deg c. temp. uniformity in
working chamber. Uniform forced air circulate across the shelf via
air diffusers on the top wall.
Uniform horizontal or vertical airflow shall be provided for maintaining uniform temperature and RH in the room. System for adjustable forced air exchange shall be provided with up to 20 air exchanges per hour of fresh air to the room or its equivalent and an option to shut it down when not required. No direct radiation on the specimen.
Uniform horizontal or vertical airflow shall be provided for maintaining uniform temperature and RH in the room. System for adjustable forced air exchange shall be provided with up to 20 air exchanges per hour of fresh air to the room or its equivalent and an option to shut it down when not required. No direct radiation on the specimen.
Heating / Humidification & Dehumidification :
Custom built stainless steel tubular heaters are used as
heating element. The stainless steel fins ensure better heat transfer.
Humidity is controlled by steam injection method. The boiler tank is used for steam generation; Electro-magnetic switch is used for sensing the Water Level. Thus eliminating the humidity interruption. De-humidification coils are installed below the cooling coils for lower humidity.
Humidity is controlled by steam injection method. The boiler tank is used for steam generation; Electro-magnetic switch is used for sensing the Water Level. Thus eliminating the humidity interruption. De-humidification coils are installed below the cooling coils for lower humidity.
Certification :
- MSME AWARD FOR BEST MANUFACTURING PRACTICES – 2023
- ISO/IEC 17025: 2017 / Electrical Safety IEC 61010.
- ISO 45001:2018 / ISO 14001:2015 & WHO-GMP
- ISO 9001:2015 certified Co. & CE marked product.
- RoHS 2002/95/EC / UL (QAMS Certification).
- US FDA Certification.
- NSIC & MSME registered.
- ·D&B registered (Financial Certification).
Sensor :
Radix / Rotronic Make Hygroclip non condensing type
sensor for RH and PT-100 ‘A’ class for temp. calibrated from
ERTL / NABL accredited labs.
Power Supply :
Single Phase 230V AC, 50Hz.
Safety Features :
2 minute compressor “on” delay timer to safeguard the compressor. Compressors overload relay protector. Electronic low water level cut
off device to cut off the supply to boiler heater in case of low water level. Safety Temp. Controller. MCB for mains.
- Unit will be provided with safety devices for temperature and humidity overshoot in case of malfunction.
- Built-in temp. Deviation, audio/visual alarms.Safety thermostat for over shooting of temp. Safety circuit to cut off the whole system.
- OLP (Overload Protector) & Time delay Circuit for safety of compre
- HRC fuses for compressors, Heaters & Mains.
Documentation :
To comply with the documentation requirements, we provide
IQ, OQ & PQ protocols to be executed before taking the chamber
in to for regular use, and support the supply with the following
documents with the detail operational and service manual.
Standard Operating Procedure (SOP)
Operational Manual for Controller IQ,PQ,OQ protocols certificate.
Calibration certificate of all controlling modules with traceable to NABL / ERTL accredited labs. Certificate of MOC.
Test Report of chamber prior to supply with mapping certificate.
wiring diagram for ease of service maintenance.
Standard Operating Procedure (SOP)
Operational Manual for Controller IQ,PQ,OQ protocols certificate.
Calibration certificate of all controlling modules with traceable to NABL / ERTL accredited labs. Certificate of MOC.
Test Report of chamber prior to supply with mapping certificate.
wiring diagram for ease of service maintenance.