Ultra Low Temp. Circulation Bath Cryostat

Ultra Low Temp. Circulation Bath Cryostat
Model : SRL / ULB-19

Application :

These equipments are used for climatic & durability tests of electrical & electronic components, corrosion test on mechanical assemblies, materials for simulated tropical & extreme tropical conditions.

Temp. Range :

-10°C to -80°C
Resolution : 0.1°C
Temp. Fluctuation : + 0.2°C,
Temp. Uniformity : + 2°C

Controller : [PLC with HMI TFT screen]

Standard PID : Provides Precise Temperature, Maintain Uniform And Accurate Growth Environment, Timer, Alarm, Auto-Tuning And Auto Start Stop Function. Technical Design and Construction Silent Fan Motor to Maintain Uniform Temperature Over Temperature and Current Protection Capability Ensure User Safety, Adjustable Sliding Rack, Alert Unexpected Interruption Of Electrical Power Or Unauthorized Change.

Refrigeration System : (Air Cooled)

Emerson / Danfoss / Tecumseh : make compressors, 2 stage cooling system with Cascade system for ULTRA LOW TEMP. Range & Single stage system for Humidity Control. All accessories such as HPCO/LPCO, Oil Separators, Dryers, Relays, OLP etc. of Danfoss/Tecumseh Emerson Make. CFC free refrigerant to be used to comply with the New Environmental Regulation. Will have suitable tonnage compressor for maintain temperature with lights on. Will have hermetically sealed condensing unit compressor coupled with Evaporation coil and condenser, safe guarded by time delay circuit. Cabinet shall be supplied with air-cooled condensing unit with extended compressor life and close temperature control. Cooling system will be split type to place condenser unit in a ventilated area to avoid hot air in growth chamber. Cooled air shall be delivered in such a way to reduce or eliminate condensation within media dishes and to provide maximum uniformity In different research vessels. This may be through silent and durable fan motors or through any kind of advanced air diffusers. Air Cooled Condenser with solenoid & LP to pass hot gas to the chamber for uniformity & long life of compressor for continuous usage. Phenolic coating for cooling & condensing coils (All weather proof).

Circulation :

The Ultra low temp. circulation bath is provided with best circulation to give better temperature uniformity this is achieved by using one set of motor & blower in baffle wall Compartment to push treated air in working chamber. This system gives better temperature uniformity in working chamber.

Cabinet Construction & Insulation :

MOC of the Chamber will be: Double walled Chamber with Inner of stainless steel 304 grade & outer of CRCA duly powder coated, PUF Insulation in between two walls.

  • Double door, inner door of glass with frame & silicon gasket sealing, outer door metallic with PUF insulation.
  • The unit will be made of double walled leak proof metal door with lock, with a provision of opening door from inside.
  • Forced air circulation for uniform temperature.
  • Lockable & Movable PU wheels for easy movement.
  • Optional : [PLC with HMI touch screen]

    PLC Control system with touch screen display & HMI for data Storage, data logger reading & audit trail, Door access & SMS records, Email alert. Data Logger 1 temp + 1 RH. Data Logger with LCD display window capable to store non volatile data memory up to 5000 readings with audit trail facility complies 21 CFR Part 11. Change over to stand by system automatically as per schedule or on detecting fault with current system Temperature & Humidity overshoot and under shoot protection Mobile Alarm system, Door Access, system setting reset , Graph, SMS, Email alert, etc. In built PC port for connectivity for PC base operation of data management.

    Power Supply :

    Single Phase 230V AC, 50Hz / Three Phase 440V AC, 50Hz

    Sensor :

    Sensors : PT-100 ‘A’ class for temp. calibrated from ERTL / NABL accredited labs.

    Certification :

    ISO 9001:2015 Certified Co. D&B registered & CE mark product.
    ISO 14001:2015 & WHO-GMP
    NSIC & MSME registered
    Calibration & validation certificates traceable to NABL / ERTL accredited labs.

    Safety Features :

    2 minute compressor “on” delay timer to safeguard the compressor. Compressors overload relay protector. Electronic low water level cut off device to cut off the supply to boiler heater in case of low water level. Safety Temp. Controller. MCB for mains.

  • Unit will be provided with safety devices for temperature and humidity overshoot in case of malfunction.
  • Built-in temp. Deviation, audio/visual alarms. Safety thermostat for over shooting of temp. Safety circuit to cut off the whole system.
  • OLP (Overload Protector) & Time delay Circuit for safety of compressors.
  • HRC fuses for compressors, Heaters & Mains.
  • Documentation :

    To comply with the documentation requirements, we provide IQ, OQ & PQ protocols to be executed before taking the chamber in to for regular use, and support the supply with the following documents with the detail operational and service manual.
    Standard Operating Procedure (SOP) Operational Manual for Controller IQ,PQ,OQ protocols certificate.
    Calibration certificate of all controlling modules with traceability.
    Certificate of MOC.
    Test Report of chamber prior to supply with mapping certificate.
    wiring diagram for ease of service maintenance.