Walk in Burn in Chamber
- Home
- Products
- Walk in Burn in Chamber
- Algal Growth Chamber
- Accelerated Ageing Chamber
- Arabidopsis Growth Chamber
- Photo Stability Chamber
- Drosophila Chamber
- Seed Germinator Single Chamber
- Seed Germinator Dual Chamber
- Insect Growth Chamber
- Walk In Seed Germinator Chamber
- Laminar Air Flow
- Plant Growth Chamber
- Walk In Plant Growth Chamber
- Accelerated Ageing Oven
- Cooling Cabinet Model : SRL / CCH-02
- Accelerated Weathering Chamber Model SRL / AWC-12
- Thermal Hot and Cold Chamber Model : SRL / HCCH-02
- Humidity Chamber MODEL : SRL / HC-09
- Horizontal Rectangular Autoclave / Sterilizer Model : SRL/AC-58
- Seed Storage Cabinet Model : SRL / SSC-22
- Cold Chamber Model : SRL / CCH-02
- Walk In Humidity Chamber Model : SRL / WIHC-12
- Walk In LN2 Chamber Model : SRL / WILN2-12
- Walk In Hot & Cold Chamber
Our Brouchers
Download
Get in Touch
Location:
goregaon (East) Mumbai, Maharashtra- 400063.
Mail Us On :
sales@srlabinstruments.com
info@srlabinstruments.com
Make a Call :
022 2685 8753
022 26858362
Walk in Burn in Chamber Model : SRL / WIBIC-12
Application :
A walk-in burn-in chamber is used for testing the reliability and
performance of large or multiple products by simulating harsh
environmental conditions, such as high temperatures. Its
applications include accelerated aging and durability tests for
electronic components, automotive parts, and medical devices,
as well as for storing large quantities of samples under controlled
conditions.
Ecocentric System :
Chamber runs on the basis of Dewpoint control. Less deviations
during short-term door opening & power failure. Less utility area
Increased storage area. Low operating cost. Minimum power &
water consumption. Reduced deviations. Less breakdowns due
to standby refrigeration & humidification system. Due to PLC
HMI & controlling through microprocessor based PID Temp. &
RH operations the on time of both Temp. & RH system is
reduced & efficiency of this system is increased with reduced
energy consumption
Heating System :
Nichrome wire coiled or strip heaters or tubular heaters are used
depending upon the design of the which may vary with the
specific application and this should be conveyed to us by the
user to ensure optimum performance parameters. A port hole of
suitable dimension will be provided for giving power outside.
Controller : [PLC with HMI TFT screen] :
MOC of the Chamber will be: Double walled Chamber with Inner & outer
of GI duly pre painted, PUF Insulation in between two walls.
- Flooring: 2 mm aluminum chequer plates.
- The unit will be made of double walled leak proof metal door with lock, with a provision of opening door from inside
- Forced air circulation for uniform temperature.
Power Supply :
Single Phase 230V AC, 50Hz / Three Phase 440V AC, 50Hz
Air Circulation : [Laminar Type]
The chamber is provided with best air circulation to give better temperature uniformity this is achieved by using one set of motor & blower in baffle wall Compartment to push treated air in working chamber. This system gives better than 1 deg c. temp. uniformity in working chamber.Uniform forced air circulate across the shelf via air diffusers on the top wall. Uniform horizontal or vertical airflow shall be provided for maintaining uniform temperature and RH in the room. System for adjustable forced air exchange
shall be provided with up to 20 air exchanges per hour of
fresh air to the room or its equivalent and an option to
shut it down when not required. No direct radiation on the
specimen.
Optional :
To be provided with air flow regulator adjustable 0.2 m/s operated from PLC & HMI.
Optional :
To be provided with air flow regulator adjustable 0.2 m/s operated from PLC & HMI.
Controller : [PLC with HMI TFT screen]
PID Action : Provides Precise Temperature, Maintain Uniform And Accurate Growth Environment, Timer, Alarm, Auto-Tuning And Auto Start Stop Function. Technical Design and Construction Silent Fan Motor to Maintain Uniform Temperature Over Temperature and Current Protection Capability Ensure User Safety, Adjustable Sliding Rack, Alert Unexpected Interruption Of Electrical Power Or Unauthorized Change.
Optional : [PLC with HMI TFT screen]
PLC-HMI Control system with touch screen display & HMI for data Storage, Stepwise Programmable Controller with 10 or more programs Provides Automatic Operation of Variable Temperature, Humidity Value, 50 Or More Cycles with Minimum 100 Sections in Each Cycle. Data logger with RS 485/232 port for logging & transfer of data. Auto restart, power failure event logging, memory protection S.M.A.R.T/ SELF diagnostics system. Control system shall have audio/audiovisual warning/alarm when set temperature/RH is below or above the set values. Ethernet communication port. Ambient temp. Monitoring. Over Temp. and Current Protection Capability Ensure User Safety, Adjustable Sliding Rack, Water Level Sensor Alert Control System. Total no of output: 23 channels. Alert Unexpected Interruption of Electrical Power or Unauthorized Change.4 digit Password lock.
Optional : [PLC with HMI TFT screen]
PLC-HMI Control system with touch screen display & HMI for data Storage, Stepwise Programmable Controller with 10 or more programs Provides Automatic Operation of Variable Temperature, Humidity Value, 50 Or More Cycles with Minimum 100 Sections in Each Cycle. Data logger with RS 485/232 port for logging & transfer of data. Auto restart, power failure event logging, memory protection S.M.A.R.T/ SELF diagnostics system. Control system shall have audio/audiovisual warning/alarm when set temperature/RH is below or above the set values. Ethernet communication port. Ambient temp. Monitoring. Over Temp. and Current Protection Capability Ensure User Safety, Adjustable Sliding Rack, Water Level Sensor Alert Control System. Total no of output: 23 channels. Alert Unexpected Interruption of Electrical Power or Unauthorized Change.4 digit Password lock.
Temp. Range :
Temp Range : Above ambient 5°C to 100°C
Accuracy : 0.2°C
Uniformity : ±2°C
Accuracy : 0.2°C
Uniformity : ±2°C
Air Circulation : [Laminar Type]
The chamber is provided with best air circulation to give better temperature uniformity this is achieved by using one set of motor & blower in baffle wall Compartment to push treated air in w orking chamber. This system gives better than 1 deg c. temp. uniformity in working chamber.
Uniform forced air circulate across the shelf via air diffusers on the top wall. Uniform horizontal or vertical airflow shall be provided for maintaining uniform temperature and RH in the room. System for adjustable forced air exchange shall be provided with up to 20 air exchanges per hour of fresh air to the room or its equivalent and an option to shut it down when not required.
Certification :
- MSME AWARD FOR BEST MANUFACTURING PRACTICES – 2023
- ISO/IEC 17025: 2017 / Electrical Safety IEC 61010
- ISO 45001:2018 / ISO 14001:2015 & WHO-GMP
- ISO 9001:2015 certified Co. & CE marked product
- RoHS 2002/95/EC / UL (QAMS Certification)
- US FDA Certification
- NSIC & MSME registered
- D&B registered (Financial Certification)
Documentation :
To comply with the documentation requirements, we provide IQ, OQ & PQ protocols to be executed before taking the chamber in to for regular use, and support the supply with the following documents with the detail operational and service manual.
Standard Operating Procedure (SOP)
Operational Manual for Controller
IQ,PQ,OQ protocols certificate.
Calibration certificate of all controlling modules with traceable to NABL / ERTL accredited labs.
Certificate of MOC.
Test Report of chamber prior to supply with mapping certificate.
wiring diagram for ease of service maintenance.
Standard Operating Procedure (SOP)
Operational Manual for Controller
IQ,PQ,OQ protocols certificate.
Calibration certificate of all controlling modules with traceable to NABL / ERTL accredited labs.
Certificate of MOC.
Test Report of chamber prior to supply with mapping certificate.
wiring diagram for ease of service maintenance.