Environmental Chamber with Solar Simulator
- Home
- Products
- Environmental Chamber with Solar Simulator
- Algal Growth Chamber
- Accelerated Ageing Chamber
- Arabidopsis Growth Chamber
- Photo Stability Chamber
- Drosophila Chamber
- Seed Germinator Single Chamber
- Seed Germinator Dual Chamber
- Insect Growth Chamber
- Walk In Seed Germinator Chamber
- Laminar Air Flow
- Plant Growth Chamber
- Walk In Plant Growth Chamber
- Accelerated Ageing Oven
- Cooling Cabinet Model : SRL / CCH-02
- Accelerated Weathering Chamber Model SRL / AWC-12
- Thermal Hot and Cold Chamber Model : SRL / HCCH-02
- Humidity Chamber MODEL : SRL / HC-09
- Horizontal Rectangular Autoclave / Sterilizer Model : SRL/AC-58
- Seed Storage Cabinet Model : SRL / SSC-22
- Cold Chamber Model : SRL / CCH-02
- Walk In Humidity Chamber Model : SRL / WIHC-12
- Walk In LN2 Chamber Model : SRL / WILN2-12
- Walk In Hot & Cold Chamber
Our Brouchers
Download
Get in Touch
Location:
goregaon (East) Mumbai, Maharashtra- 400063.
Mail Us On :
sales@srlabinstruments.com
info@srlabinstruments.com
Make a Call :
022 2685 8753
022 26858362
Environmental Chamber with Solar Simulator
Model NO : SRL / ECH - 01
Application :
These equipments are used for climatic & durability tests of electrical
& electronic components, corrosion test on mechanical assemblies,
materials for simulated tropical & extreme tropical conditions.
Ecocentric System :
Chamber runs on the basis of Dewpoint control. Less deviations
during short-term door opening & power failure. Less utility area
Increased storage area. Low operating cost. Minimum power &
water consumption. Reduced deviations. Less breakdowns due
to standby refrigeration & humidification system. Due to PLC
HMI & controlling through microprocessor based PID Temp. &
RH operations the on time of both Temp. & RH system is
reduced & efficiency of this system is increased with reduced
energy consumption.
Salient Features : [Optional]
First time in India developed by SR Lab Instruments.
Standby Refrigeration, Standby Humidification & Standby safety
controller with auto changeover, In case of failure of the main
system, To run the system for a longer with uninterrupted
operation.
Also USFDA approved 21 CFR compliance software, where in
case of temp. & RH fluctuation, SMS & Email alert shall be sent
to registered user nos and minute details of operation of the
chamber can be downloaded weekly, Monthly or Quarterly.
Construction :
Double walled in construction inner made of SS 304 & outer made of
CRCA powder coated with PUF & ceramic wool Insulation in between
two walls.
- Door with silicon gasket sealing, metallic with PUF insulation.
- The unit will be made of double walled leak proof metal door with lock
- Forced air circulation for uniform temperature.
- Lockable & Movable PU wheels for easy movement Insulation of Walls, ceiling and floor: 80mm thick puff plus ceramic wool Insulation with puff in-place density of minimum of 1kg per cubic foot or its equivalent. Insulation with expended polystyrene or any equivalent material having R factor of minimum 34. Insulation material shall maintain its dimensional stability in an operating temperature range of Insulation puff.
Door : Flush type doors of metal surfaces (as per above specification of metal) with proper puff insulation of above mentioned standard or its equivalent. Doors shall have magnetic snap-in perimeter gasket or its equivalent, self-closing cam lift gravity hinges or its equivalent, a posi-seal door closure or its equivalent. Door shall have key lockable latch handle. Doorjambs shall be made fiberglass reinforced plastic or any other suitable material compatible with constructed door.
Viewing Window : Suitable doors with together glass window with organ gas Coating to Prevent Coalesced on glass (20 x 20 cm) with its appropriate shutter
Sensor :
Rotronic Make Hygroclip non condensing type
sensor for RH and PT-100 ‘A’ class for temp. calibrated from
ERTL / NABL accredited labs.
Refrigeration system : (Air Cooled)
Emerson / Danfoss / Tecumseh: make compressors,
2 stage cooling system with Cascade system for ULTRA LOW
TEMP. Range & Single stage system for Humidity Control. All
accessories such as HPCO/LPCO, Oil Separators, Dryers,
Relays, OLP etc. of Danfoss/Tecumseh Emerson Make.
CFC free refrigerant to be used to comply with the New
Environmental Regulation. Will have suitable tonnage compressor
for maintain temperature with lights on. Will have hermetically
sealed condensing unit compressor coupled with Evaporation coil
and condenser, safe guarded by time delay circuit. Cabinet shall
be supplied with air-cooled condensing unit with extended
compressor life and close temperature control. Cooling system
will be split type to place condenser unit in a ventilated area to
avoid hot air in growth chamber. Cooled air shall be delivered in
such a way to reduce or eliminate condensation within media
dishes and to provide maximum uniformity In different research
vessels. This may be through silent and durable fan motors or
through any kind of advanced air diffusers. Air Cooled Condenser
with solenoid & LP to pass hot gas to the chamber for uniformity
& long life of compressor for continuous usage. Phenolic coating
for cooling & condensing coils (All weather proof).
Controller :
PID Action : Provides Precise Temperature, Maintain Uniform
And Accurate Growth Environment, Timer, Alarm, Auto-Tuning
And Auto Start Stop Function. Technical Design and Construction
Silent Fan Motor to Maintain Uniform Temperature Over
Temperature and Current Protection Capability Ensure User Safety,
Adjustable Sliding Rack, Alert Unexpected Interruption Of Electrical
Power Or Unauthorized Change
Optional : [PLC with HMI touch screen]
PLC Control system with touch screen display & HMI for data Storage, Stepwise Programmable Controller with 50 or more programs Provides Automatic Operation of Variable Temperature, Humidity Value, 100 Or More Cycles with Minimum 100 Sections in Each Cycle. Data logger with RS 485/232 port for logging & transfer of data. Auto restart, power failure event logging, memory protection S.M.A.R.T/ SELF diagnostics system. Control system shall have audio/audiovisual warning/alarm when set temperature/RH is below or above the set values. Ethernet communication port. Ambient temp. Monitoring. Over Temperature and Current Protection Capability Ensure User Safety, Adjustable Sliding Rack, Water Level Sensor Alert Control System. Total no of output: 23 channels. Alert Unexpected Interruption of Electrical Power or Unauthorized Change.4 digit Password lock.
Optional : [PLC with HMI touch screen]
PLC Control system with touch screen display & HMI for data Storage, Stepwise Programmable Controller with 50 or more programs Provides Automatic Operation of Variable Temperature, Humidity Value, 100 Or More Cycles with Minimum 100 Sections in Each Cycle. Data logger with RS 485/232 port for logging & transfer of data. Auto restart, power failure event logging, memory protection S.M.A.R.T/ SELF diagnostics system. Control system shall have audio/audiovisual warning/alarm when set temperature/RH is below or above the set values. Ethernet communication port. Ambient temp. Monitoring. Over Temperature and Current Protection Capability Ensure User Safety, Adjustable Sliding Rack, Water Level Sensor Alert Control System. Total no of output: 23 channels. Alert Unexpected Interruption of Electrical Power or Unauthorized Change.4 digit Password lock.
Air Circulation : [Laminar type]
The chamber is provided with best air circulation to give better
temperature uniformity this is achieved by using one set of motor
& blower in baffle wall Compartment to push treated air in w
orking chamber. This system gives better than 1 deg c. temp.
uniformity in working chamber.
Uniform forced air circulate across the shelf via air diffusers
on the top wall. Uniform horizontal or vertical airflow shall
be provided for maintaining uniform temperature and RH
in the room. System for adjustable forced air exchange
shall be provided with up to 20 air exchanges per hour of
fresh air to the room or its equivalent and an option to
shut it down when not required. No direct radiation on the
specimen
Temp. & Humidity Range :
+10°C to +80°C Resolution : 0.1 °C
Temperature Fluctuation : + 0.2°C, Temp. Uniformity : + 2 °C
Humidity Range : 10% to 95% RH, Resolution : 0.1% Accuracy : + 2%R.H, Uniformity : ~+ 5%
Temperature Fluctuation : + 0.2°C, Temp. Uniformity : + 2 °C
Humidity Range : 10% to 95% RH, Resolution : 0.1% Accuracy : + 2%R.H, Uniformity : ~+ 5%
Xenon Short Arc Lamp :
150 / 300 / 500W Max current 25 amp, Voltage 20V max, Ozen
free and about 1000 hours life time in the centre of the chamber
for light illumination in solar wavelength.
Heating / Humidification & Dehumidification :
Imported Encolite heaters up to 3 K.W. Air Heaters are provided for
heating above ambient temperatures.
Humidity is controlled by steam injection method. The boiler tank is
used for steam generation, Electro-magnetic switch is used for
sensing the Water Level. Thus eliminating the humidity interruption.
De-humidification coils are installed below the cooling coils
for lower humidity.
Power Supply :
Single Phase 230V AC, 50Hz / Three Phase 440V AC, 50Hz
500 watts power supply – 1 no. with current adjustment and
current, voltage digital indicator, suitable to connect xenon light
source and to get its variable intensity.
Certification :
- MSME AWARD FOR BEST MANUFACTURING PRACTICES – 2023
- ISO/IEC 17025: 2017 / Electrical Safety IEC 61010.
- ISO 45001:2018 / ISO 14001:2015 & WHO-GMP
- ISO 9001:2015 certified Co. & CE marked product.
- RoHS 2002/95/EC / UL (QAMS Certification).
- US FDA Certification.
- NSIC & MSME registered.
- D&B registered (Financial Certification)
Shelves & Trays :
Stainless Steel 304 quality bar type shelves will be fitted inside
the chamber adjustable up to 0.5 inches Increment/Decrement.
[Qty: 02 Nos]
Safety Features :
2 minute compressor “on” delay timer to safeguard the compressor.
Compressors overload relay protector. Electronic low water level cut
off device to cut off the supply to boiler heater in case of low water
level. Safety Temp. Controller. MCB for mains.
- safety devices for temperature and humidity overshoot in case of malfunction.
- Built-in temp. Deviation, audio/visual alarms.Safety thermostat for over shooting of temp. Safety circuit to cut off the whole sys
- OLP (Overload Protector) & Time delay Circuit for safety of compre
- HRC fuses for compressors, Heaters & Mains.
Documentation :
To comply with the documentation requirements, we provide IQ, OQ & PQ protocols to be executed before taking the chamber in to for regular use, and support the supply with the following
documents with the detail operational and service manual.
Standard Operating Procedure (SOP) Operational Manual for Controller
IQ,PQ,OQ protocols certificate.
Calibration certificate of all controlling modules with traceable to NABL / ERTL accredited labs.
Certificate of MOC.
Test Report of chamber prior to supply with mapping certificate.
wiring diagram for ease of service maintenance.
Standard Operating Procedure (SOP) Operational Manual for Controller
IQ,PQ,OQ protocols certificate.
Calibration certificate of all controlling modules with traceable to NABL / ERTL accredited labs.
Certificate of MOC.
Test Report of chamber prior to supply with mapping certificate.
wiring diagram for ease of service maintenance.